Technical coating guidance
Fire Safety Paint for Walls
Fire Safety Paint for Walls is selected when projects require passive fire protection support with substrate-specific performance planning, application control, and long-term service reliability.
This page helps project teams review manufacturer price, approved system details, top coat compatibility, and project quantity planning for large B2B requirements.
Related terms include Fire Safety Coating for Walls, and both coating and paint variants are useful for comparing project requirements.
Technical Purchase Guidance
Before procurement, share substrate type, area, expected fire rating duration, project location, and required standard. This helps technical teams recommend a suitable system for estimation and compliance checks.
AMEETUFF follows a strict professional code while supporting customers through pre-sales technical consultation, application guidance, and project quotation support.
Centre Government Lab Tested. For details, mail info@ameetuff.in or call 9811013830.
Quotation and Datasheet Support
01
Request price and quote
Share project area, substrate, and city for commercial quotation support.
02
Ask for datasheet
Get technical details for consultant approval and procurement planning.
03
Confirm system fit
Match coating build and application method with fire-rating requirement.
Technical datasheet evidence
Wall and Gypsum Board Fire Coating Datasheets
These ARC 318 technical datasheets support wall, concrete, plastered wall, corridor, staircase, basement and commercial interior fire coating selection.
ARC 318
Fire Resistant Insulation Grade Coating
Water based fire resistant base coat and water based fire resistant top coat system for wall, concrete, gypsum board, and rock surfaces.
- Recommended use
- Walls, concrete, gypsum board, roof/wall surfaces, rock surfaces, partitions, and interior building surfaces requiring fire and heat-transfer reduction.
- Fire test / standards mentioned
- TDS mentions flame spreading rate as nil as per UL 94 and BS 476 Part 7.
- Fire protection note
- Material requirement is given for 30, 60, 90, and 120 minute fire rating systems depending on coat build and consumption.
- Application method
- Clean and dry the surface, remove loose old coating by sanding if required, apply base coat and top coat by brush or roller, and allow fire testing after 8 days.
System build
Base coat plus top coat
Consumption - 30 min
Approx. 500 gm/sq. m
Consumption - 60 min
Approx. 1000 gm/sq. m
Consumption - 90 min
Approx. 1500 gm/sq. m
Consumption - 120 min
Approx. 1800 gm/sq. m
Coverage
2-3 sq. m/kg for primary coat and top coat
Temperature resistance
1025 C for primary and top coat
Storage life
6 months
Download ARC 318 PDF
ARC 318 PR
Fire Resistant Ceramic Insulation Primer Coating
Water based rough finish high-grip ceramic insulation primer/base coat for wall, gypsum board and concrete.
- Recommended use
- Gypsum board, concrete walls, fire rated partitions, cement board, ceiling systems, fire resistant wall systems, commercial and industrial buildings.
- Fire test / standards mentioned
- TDS presents it as a fire resistant ceramic insulation primer/base coat for wall and gypsum systems.
- Fire protection note
- Recommended consumption is aligned to 30, 60, 90, and 120 minute system requirements.
- Application method
- Apply on clean, dry surface free from dust, oil, grease, loose particles, and weak old coating. Two primer coats are recommended before compatible ARC 318 TC top coat.
Finish
Rough texture matte
DFT per coat
300-700 microns per coat
Recommended WFT
500-1100 microns
Coverage
1.5-2.5 sq. m/kg depending on surface
Recoat time
4-6 hours
VOC
Very low
Solid content
Approx. 65 +/- 5%
Pack size
25 kg
Download ARC 318 PR PDF
Final coating build, primer requirement, surface preparation, and fire rating duration should be confirmed against actual wall or board condition, project specification, and approving authority requirements.
Related Fire Protection Pages