Product details
Fire Stop Board and Fire Stop Barrier Systems
Fire STOP BOARDS are designed to improve safety and fire resistance of HT and LT cable routes and help control spread of flame through service openings. They support compliance with Indian and British safety standard BS 476 for domestic and commercial fire regulations.
Fire stop board can make a major safety difference during fire events by creating critical delay between fire start and fire spread, supporting evacuation and emergency response.
Fire Stop Barrier is a passive fire protection system used to prevent spread of fire, smoke, and hot gases through openings, joints, and service penetrations in fire-rated walls and floors. It helps maintain integrity of fire compartments by sealing gaps around cables, ducts, pipes, and structural joints.
Commercial and Project Applications
Fire stop board systems are widely used in electrical shafts, duct crossings, cable tray penetrations, data centers, utility corridors, industrial plants, and large commercial buildings.
For projects requiring fire stop board supplier, fire stop duct barrier manufacturer, fire stop cable barrier price, and firestop barrier system datasheet, Ameetuff provides technical and procurement support.
These boards are commonly integrated with fire stop sealants and mortar to build a complete compartmentation solution.
AMEETUFF abides by a strict code of professional ethics when it comes to our business and customers. We invite you to review our products on Google. We have articles and other information of interest on our site.
Centre Government Lab Tested. For more details, mail at info@ameetuff.in or call 9811013830.
Quotation and Datasheet Support
01
Request board price and quote
Share opening size, cable or duct type, wall thickness, and project location details.
02
Ask for datasheet
Get fire stop board installation guidance and supporting system recommendations.
03
Confirm fire stop assembly
Align board, sealant, mortar, and penetration type before purchase and execution.
Technical datasheet evidence
Fire Stop Barrier System Datasheets
These fire stop barrier datasheets support project review for cable, duct, pipe and mixed service penetrations where fire compartmentation, smoke sealing and mechanical protection are required.
ARC 375A
Composite Sheet Fire Stop Barrier System
Modular passive fire protection assembly for service penetrations through fire-rated walls and floors.
- Recommended use
- Wall-to-wall and floor-to-floor openings, duct joints, cable trays, GI ducts, HVAC penetrations, hydrant pipes, sprinkler lines, electrical shafts, service risers and utility corridors.
- Fire test / standards mentioned
- TDS mentions NABL accredited laboratory testing and fire resistance references including BS 476 Part 20, UL 1479, ISO 834 and IS 12458.
- Fire protection note
- Designed to maintain compartmentation and prevent passage of fire, smoke and hot gases through mixed service penetrations.
- Application method
- Clean and inspect the opening, apply approved sealant, fix intumescent board, fill gaps with treated insulation wool, install stainless steel composite sheet and finish with fire stop sealant.
System type
Composite sheet fire stop barrier
Main components
Intumescent board, treated insulation wool, sealants and stainless steel composite sheets
Suitable services
Cables, pipes, ducts and mixed penetrations
Service areas
Data centres, basements, plant rooms, tunnels and service corridors
Inspection
Clean, inspectable and maintainable system
Identification
Ameetuff fire stop identification label
Download ARC 375A PDF
Fire and Smoke Stop System
Ameetuff Fire Stop Barrier System Brochure
Passive fire and smoke stop barrier system for compartmentation around cables, ducts, pipes and building service penetrations.
- Recommended use
- Electrical cable fire stop barriers, duct fire stop barriers, communication data wire fire stop barriers and hydrant pipe fire stop barriers.
- Fire test / standards mentioned
- Brochure describes fire-rated compartmentation for building safety and references BS 476 for duct fire stop barrier context.
- Fire protection note
- Supports containment of fire, smoke and toxic gases by sealing service gaps in walls, floors and technical routes.
- Application method
- Assess penetrations, prepare surfaces, install mortar, insulation wool, sealants and fire resistant coating, then inspect and allow curing where required.
System purpose
Prevent fire spread and protect critical infrastructure
Barrier types
Cable, duct, data wire and hydrant pipe barriers
Core materials
Fire resistant mortar, duct sealant, insulation wool and cable coating
Typical applications
Wall-to-wall and floor-to-floor service openings
Curing guidance
Brochure mentions 72 hours for curing or hardening where applicable
Download Fire and Smoke Stop System PDF
ARC 244 SB
Fire Stop Barrier Sealant
Silicon polymer based flexible fire resistant elastomeric sealant for fire stop barrier and duct joint sealing work.
- Recommended use
- Fire stop barrier sealing, duct joints, metal-to-metal surfaces, air flow insulation systems and areas needing chemical and corrosion protection.
- Fire test / standards mentioned
- TDS mentions water vapor and air transmission as per ASTM E96 with value less than 0.01 perm.
- Fire protection note
- TDS notes no spread of fire when dry, good fire retardant properties and temperature resistance up to 800 C to 900 C.
- Application method
- Apply by spatula on cleaned joint or barrier seal area after confirming gap condition and compatible surface preparation.
Colour
Off white, black or grey
Specific gravity
1.29
Solubility
Water soluble
Drying time
3 to 4 hours
Complete hard dry
48 hours
Chemical nature
Silicon polymer compound
Particle size
Less than 5 micron
Storage life
9 months
Download ARC 244 SB PDF
Final barrier assembly, board thickness, sealant quantity, opening preparation and fire rating should be confirmed against actual penetration details, site condition and approving authority requirements.
Related Fire Protection Applications
For complete passive fire protection planning, connect this page with Fire Stop Barrier for HT and LT Cables, Fire Retardant Organic Sealant, Fire Resistant Mortar, and Fire Resistant Coating for Duct.
For broader category access, use Fire Retardant Coating, and for support use FAQ or Contact.